iir — iir digital filter
[hz]=iir(n,ftype,fdesign,frq,delta)
positive number witn inteher value, the filter order.
string specifying the filter type, the possible values are:
'lp' for low-pass,'hp' for
high pass,'bp' for band pass and
'sb' for stop band.
string specifying the analog filter design, the
possible values are: 'butt',
'cheb1', 'cheb2' and
'ellip'
2-vector of discrete cut-off frequencies (i.e.,
0<frq<.5). For 'lp' and
'hp' filters only frq(1) is
used. For 'bp' and 'sb' filters
frq(1) is the lower cut-off frequency and
frq(2) is the upper cut-off frequency
2-vector of error values for cheb1,
cheb2, and ellip filters where
only delta(1) is used for
cheb1 case, only delta(2) is
used for cheb2 case, and
delta(1) and delta(2) are both
used for ellip case.
0<delta(1),delta(2)<1
for cheb1 filters
1-delta(1)<ripple<1 in passband
for cheb2 filters
0<ripple<delta(2) in stopband
for ellip filters
1-delta(1)<ripple<1 in passband and
0<ripple<delta(2) in stopband
function which designs an iir digital filter using analog filter designs and bilinear transformation .